TM 5-3805-293-10
0021
INSTALLATION
00021
WARN I N G
Ether fuel is extremely flammable and toxic. DO NOT smoke, and make sure you are in a
well-ventilated area away from heat, open flames or sparks. Wear eye protection. Avoid
contact with skin and eyes and avoid breathing ether fumes. If fluid enters or fumes irritate
the eyes, wash immediately with large quantities of clean water for 15 minutes. Seek
medical attention immediately if ether is inhaled or causes eye irritation. Failure to follow
this warning may cause serious injury or death to personnel.
Ensure gasket is properly seated in valve prior to installing cylinder. If gasket is not
properly seated, ether will escape from valve. Seek medical attention immediately if ether
is inhaled or causes eye irritation. Failure to follow this warning may cause serious injury
or death to personnel.
C AU T I O N
Make sure gasket is positioned correctly on ether starting aid cylinder before installing.
Failure to follow this caution may result in damage to gasket and ether leakage.
1. Install new gasket on valve (Figure 1, Item 3).
2. Install ether starting aid cylinder (Figure 1, Item 1) on valve.
3. Tighten clamp (Figure 1, Item 2).
END OF TASK
FOLLOW-ON TASK
00021
Close right front access door.
END OF TASK
END OF WORK PACKAGE
0021-3/(4 blank)