Table 1. Preventive Maintenance Checks and Services (PMCS) with Lubrication Information - Continued.
Figure 30. ROPS Hardware.

Operator Manual For Motorized Road Grader Model 120M
Page Navigation
  229    230    231    232    233  234  235    236    237    238    239  
img
TM 5-3805-293-10
0013
Table 1. Preventive Maintenance Checks and Services (PMCS)
with Lubrication Information - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL HOURS
SERVICE
PROCEDURE
CAPABLE IF:
a. Open left front access door.
Fuel System
99
Every 500
Prime
Engine
b. Turn engine start switch to ON
Hours or 3
position for 2 minutes.
Months
c. Verify water separator is full of
fuel.
d. If water separator is not full of
fuel, turn engine start switch OFF,
then turn engine start switch ON.
e. If water separator is still not full
Fuel system does not
of fuel after 2 minutes, notify Field
prime.
Level Maintenance.
f. Close left front access door.
100
Every 500
Exhaust
Engine and exhaust system components may be
Engine
System
extremely hot after engine is shut down. Do not touch any
Hours or 3
part of the exhaust system until engine has cooled down
Months
sufficiently. Failure to follow this warning may result in
injury to personnel.
a. Open right front access door.
b. Check exhaust system pipes,
Looseness, damage or
clamps, and muffler for looseness,
leaks are noted.
leakage, or damage.
c. Close right rear access door.