Table 1. Preventive Maintenance Checks and Services (PMCS) with Lubrication Information - Continued.
Figure 29. Tandem Drive Oil Level Check.

Operator Manual For Motorized Road Grader Model 120M
Page Navigation
  226    227    228    229    230  231  232    233    234    235    236  
img
TM 5-3805-293-10
0013
Table 1. Preventive Maintenance Checks and Services (PMCS)
with Lubrication Information - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL HOURS
SERVICE
PROCEDURE
CAPABLE IF:
95
Initial 500
Arctic
c. Inspect batteries for cracked
Battery case(s) cracked or
(Cont.) Engine
Batteries (if
cases and evidence of leaking.
leaks are evident.
Hours (or
equipped)
at first oil
change)
d. Check for missing, broken, split, Damage is noted.
or frayed battery cables or
connectors.
e. Check for damaged battery
Damage is noted.
posts.
f. If equipped with non-
maintenance-free batteries, inspect
electrolyte level in each cell. If level
is low, fill with distilled or clean
drinking water to bottom of filler
opening.
g. With the aid of an assistant,
install cover, then engage two
latches.
BOTH SIDES
0.2
Tandem Drive
a. Clean surface area around the
96
Every 500
Oil Level
oil check plug.
Engine
Hours or 3
b. Remove oil check plug.
Months
c. When tandem drive oil is full, oil Tandem drive oil level is
should trickle from check plug
low.
opening. Notify Field Level
Maintenance if oil level is low.
d. Replace oil check plug.