TM 5-3805-293-10
0013
Table 1. Preventive Maintenance Checks and Services (PMCS)
with Lubrication Information - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL HOURS
SERVICE
PROCEDURE
CAPABLE IF:
41
During
Blade and
Monitor blade and scarifier
Unusual noises or
Scarifier
operations for unusual noise or
vibrations present.
vibrations.
42
During
Overall
Watch for evidence of fluid
Class III oil or hydraulic fluid
Leakage
leakage.
leaks are present. Any fuel
leakage is evident.
43
During
Instrument
a. With machine fully warmed up, Gauges and warnings
Panel
monitor indicators and gauges and indicate an abnormal
Messenger Display.
reading.
b. If action light indicator is
Any flashing of action light
flashing, troubleshoot system (WP
indicator.
44
During
Air
Check air conditioner, heater and
Damaged or does not
Conditioner,
defroster fan for correct operation.
operate if required for
Heater and
mission.
Defroster Fan
N OT E
45
After
Overall View
Ensure machine is clean in order
to
facilitate
performance of PMCS inspections.
Class III oil or hydraulic fluid
a. Check under machine for
evidence of fluid leakages such as leaks are present. Any fuel
oil, coolant, fuel, or hydraulic fluid. leakage is evident.
Damage that would impair
b. Check machine for obvious
operation is evident.
damage that would impair
operation.
0013-19