TM 5-3805-261-34
TRANSMISSION MAINTENANCE.
14-11. Selector and Modulating Control Valve. (Sheet 4 of 7)
INSPECTION
1.
Apply compression load of 9.15 to 10.75 lb. to springs
(4, 8 and 22, Figure 14-109).
2.
Measure springs (4, 8 and 22). Length should be 1.062
inches.
3.
Measure springs (4, 8 and 22) free length. Length
should be 1.31 inches.
4.
Apply compression load of 0.476 to 0.558 lb. to spring
(14).
5.
Measure spring (14). Length should be 0.48 inch.
6.
Measure spring (14) free length. Length should be 0.89
inch.
7.
Apply compression load of 10.49 to 11.59 lb. to spring
(25).
8.
Measure spring (25). Length should be 4.06 inches.
9.
Measure spring (25) free length. Length should be 4.32
to 4.56 inches.
10. Apply compression load of 10.37 to 11.47 lb. to spring
(26).
11. Measure spring (26). Length should be 2.98 inches.
12. Measure spring (26) free length. Length should be 3.91
to 4.15 inches.
13. Inspect all other parts. Refer to Chapter 2.
Figure 14-109.
Go to Sheet 5
14-73