TM 5-3805-261-23-2
HYDRAULIC PUMP ASSEMBLY AND MOUNTING REPLACEMENT - CONTINUED
0329 00
CLEANING AND INSPECTION
Clean and inspect all parts in accordance with WP 0020 00.
INSTALLATION
1.
Install new preformed packing (37) and connector (36) on hydraulic pump assembly (4).
2.
Install new preformed packing (35) and elbow (34).
3.
Install elbow (33) on combination valve (2).
4.
Install new preformed packing (26) and connector (25).
5.
Install new preformed packing (27) and connector (28).
6.
Install four mounts (29) on mounting bracket (24).
7.
Position mounting bracket (24) on machine so hydraulic pump assembly (4) can be slid into mounting position.
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during proce-
dure. Ensure that any lifting device used is in good condition and of suitable load capacity. Keep clear of
heavy parts supported only by lifting device. Failure to follow this warning may cause injury or death to per-
sonnel.
NOTE
Hydraulic pump assembly weighs 159 lb
(72 kg).
8.
Use sling to position hydraulic pump assembly (4) on
mounting bracket (24).
9.
Install two washers (31), screws (30), and nuts (32).
10.
Position pump (4) and mounting bracket (24) over
mounting holes.
11.
Remove sling.
4
24
397-1474
0329 00-5