TM 5-3805-261-23-1
BLADE FLOAT CHECK VALVE MAINTENANCE (CCE MACHINE) - CONTINUED
0234 00
REMOVAL
CAUTION
NOTE
Tag hose assemblies before disconnecting to aid in installation.
This procedure covers maintenance of the left side blade float check valve. Follow these instructions for
the right side blade float check valve.
1.
Disconnect hose assembly (4) from elbow (2). Remove and discard preformed packing (3).
2.
Remove elbow (2) and preformed packing (1). Discard preformed packing.
3.
Disconnect hose assembly (12) from elbow (14). Remove and discard preformed packing (13).
4.
Remove elbow (14) and preformed packing (15). Discard preformed packing.
5.
Disconnect hose assembly (9) from connector (11). Remove and discard preformed packing (10).
6.
Remove connector (11) and preformed packing (16). Discard preformed packing.
7.
Disconnect hose assembly (8) from connector (6). Remove and discard preformed packing (7).
8.
Remove connector (6) and preformed packing (5). Discard preformed packing.
4
8
3
2
7
6
5
1
9
10
11
12
13
16
397-671
15
14
0234 00-2