TM 5-3805-261-23-1
TRANSMISSION MODULATION CONTROL HOUSING REPLACEMENT - CONTINUED
0149 00
REMOVAL - CONTINUED
NOTE
22
23
Lever is keyed to shaft.
9.
Remove nut (22), bolt (25), and shaft (14) from lever
(23).
24
10.
Remove key (24) from shaft (14).
25
14
397-448
CLEANING AND INSPECTION
Clean and inspect all parts in accordance with WP 0020 00.
INSTALLATION
11.
Pack rollers of bearings (21 and 20) with GAA grease.
12.
Coat outside of bearings (21 and 20) with antiseize
compound.
13.
Using an arbor press, install bearings (21 and 20) in
housing (5).
20
5
21
397-447
14
14.
Install key (16) on shaft (14).
15
15.
Position lever (15) inside housing (5) and install shaft
(14). End of shaft should be positioned 0.098 in. (2.49
mm) below cover mounting surface.
16.
Install bolt (17) on shaft (14).
16
5
17
397-443
0149 00-4