TM 5-3805-261-23-1
BLADE FLOAT LIMIT SWITCHES AND MOUNTING REPLACEMENT (CCE MACHINE) - CONTINUED 0093 00
REMOVAL - CONTINUED
4.
Remove two screws (12), cover (13), and gasket (14). Discard gasket.
NOTE
Tag wire assemblies before disconnecting to aid in installation.
9
5.
Loosen two screws (11) and disconnect two wire
assemblies (10) from switch (4).
6.
Remove grommet (9) from switch (4).
4
10
11
14
12
13
397-278
7.
Remove cotter pin (15), pin (17), and spacer (18). Dis-
card cotter pin.
8.
Remove two nuts (16), bolts (19), and bracket (7).
7
19
15
18
17
16
397-279
0093 00-3