TM 5-3805-261-23-1
BLADE FLOAT LIMIT SWITCHES AND MOUNTING REPLACEMENT (CCE MACHINE) - CONTINUED 0093 00
REMOVAL
NOTE
This procedure covers replacement for the left blade float limit switch and mounting. Follow these instruc-
tions for the right blade float limit switch and mounting.
1.
Remove retaining ring (8) from switch (4).
2.
Remove two nuts (1), washers (2), bolts (5), lockwashers (6), and switch (4) from bracket (7). Discard lockwashers.
3.
Remove retaining ring (3) from switch (4).
4
3
2
1
6
5
8
7
397-277