TM 5-3805-261-20COOLING SYSTEM TROUBLESHOOTING AND MAINTENANCE PROCEDURES.(cont)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONc.COOLING SYSTEM NOT PRESSURIZED.Step 1. Check condition of radiator cap.Tighten radiator cap. Replace radiator cap, if necessary. Refer to paragraph 6-48.Step 2. Check hoses and connections.Tighten loose connections. Replace hoses or clamps, if necessary. Refer to paragraph 6-40.Step 3. Contact Direct Support.d.PRESSURE OF OIL IN COOLING SYSTEM.Step 1. Check for proper oil weight. Refer to LO 5-3805-261-12.Drain improper weight oil. Refer to LO 5-3805-261-12. Fill with correct oil. Refer to LO 5-3805-261-12.Step 2. Check oil for contamination. Refer to LO 5-3805-261-12.Drain dirty oil. Refer to LO 5-3805-261-12. Fill with clean oil. Refer to LO 5-3805-261-12.Step 3. Check for oil leaks. Refer to LO 5-3805-261-12.Replace parts as necessary. Refer to paragraph 6-6.Step 4. Check oil pressure gage operation.Replace gage, if necessary. Refer to paragraph 6-6.Step 5. Contact Direct Support.6-116
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business