TM 5-3805-261-20FUEL SYSTEM MAINTENANCE.6-17.PrimaryElement. (Sheet 3 of 4)CLEANINGWARNINGCompressed air used for cleaningpurposes will not exceed 30 psi. Useonly with effective chip guarding andpersonal protective equipment(goggles/shield, gloves, etc.)1.Clean filter element (4). Usecompressed air. Directing the airpressure away from you, blow dirtoutward from center and then directair inward through filter screen toremove dirt.2.Clean all other parts. Refer to Chapter2.INSPECTIONNOTEManufacturer’s specifications call forreplacement of filter element after sixcleanings and replacement of secondaryfilter after three cleanings of filterelement. Refer to paragraph 6-12e.Inspect all parts. Refer to Chapter 2.Go to Sheet 46-61