TM 5-3805-261-10
SECTIONALIZATION FOR AIR TRANSPORT - CONTINUED
0019 00
ASSEMBLY - CONTINUED
WARNING
Wear eye protection when connecting pressurized hoses. Failure to follow this warning may cause injury to
personnel.
40.
Disconnect two hydraulic jumper hoses and electrical jumper harness. Install protective caps and store hoses and electri-
cal harness in tool box.
CAUTION
Two different thread types are used on driveshaft bolts. Coarse thread bolts are used on engine side of drive-
shaft. Fine thread bolts are used on pump side of driveshaft.
41.
Install the pump driveshaft (7) and U-joint (8) assembly.
42.
Install four bolts (6) on both ends of driveshaft (7). Tighten bolts to 40 lb-ft (55 Nm).
6
7
8
397-1067
43.
Install two pump driveshaft guards (3), four washers (5), bolts (4), three washers (2), and bolts (1).
1,2
3
4,5
397-1066
0019 00-30