TM 5-3805-293-23-4
0195
INSTALLATION
000195
N OT E
Install wires as tagged during removal.
1. Install positive battery cable (Figure 9, Item 2), negative battery cable (Figure 9, Item 5), clip (Figure 9, Item 4),
washer (Figure 9, Item 3), and bolt (Figure 9, Item 6) on hydraulic service pack platform (Figure 9, Item 1).
2. Connect positive battery cable (Figure 9, Item 2) and install new lockwasher (Figure 9, Item 9) and bolt (Figure
9, Item 8) on NATO slave receptacle (Figure 9, Item 10).
3. Position boot (Figure 9, Item 7) over bolt (Figure 9, Item 8).
Figure 9. Positive Battery Cable.
0195