FILLING CONTINUED
000128
4. Install new O-ring (Figure 6, Item 3) onto transmission drain plug (Figure 6, Item 1).
5. Install transmission drain plug (Figure 6, Item 1) on transmission (Figure 6, Item 2).
Figure 6. Transmission Drain Plug.
0128
6. Clean area around transmission oil level gauge/fill cap (Figure 4, Item 1).
7. Remove oil level gauge/fill cap.
N OT E
Transmission and differential refill capacity is approximately 16.5 gal. (62.5 L).
8. Fill transmission with oil through transmission oil filler tube. Refer to Lubrication Order (LO 5-3805-293-13) for
correct viscosity/grade for climate.
9. Install oil level gauge/fill cap.
END OF TASK