TM 5-3805-293-23-3
0115
REMOVAL CONTINUED
7. Remove clamp (Figure 3, Item 2), air cleaner cap (Figure 3, Item 3), clamp (Figure 3, Item 4), and extension
pipe (Figure 3, Item 1) from air filter housing (Figure 3, Item 10).
8. Remove clamp (Figure 3, Item 6) and disconnect hose (Figure 3, Item 8) from check valve (Figure 3, Item 5).
Remove hose from machine.
9. Remove clamp (Figure 3, Item 7) and check valve (Figure 3, Item 5) from air cleaner cover (Figure 3, Item 9).
Figure 3. Air Cleaner and Check Valve.
0115