TM 5-3805-293-23-3
0049
REMOVAL CONTINUED
11. Disconnect electrical connector (Figure 7, Item 9) from block (Figure 7, Item 8).
12. Disconnect hose (Figure 7, Item 11) and remove O-ring (Figure 7, Item 10) from block (Figure 7, Item 8).
Discard O-ring.
13. Disconnect electrical connector (Figure 7, Item 12) from back-up alarm (Figure 7, Item 13).
14. Remove bolt (Figure 7, Item 2), washer (Figure 7, Item 3), clip (Figure 7, Item 4), spacer (Figure 7, Item 5),
washer (Figure 7, Item 6), and nut (Figure 7, Item 7) from cooling fan gear motor frame (Figure 7, Item 23).
15. Remove bolt (Figure 7, Item 7), washer (Figure 7, Item 17), clip (Figure 7, Item 19), clip (Figure 7, Item 16),
washer (Figure 7, Item 15), and nut (Figure 7, Item 14) from hose (Figure 7, Item 1) and hose (Figure 7,
Item 11),
16. Remove bolt (Figure 7, Item 22), washer (Figure 7, Item 21) and clip (Figure 7, Item 20) from bracket (Figure 7,
Item 24).
Figure 7. Drain Line Clamps and Electrical Connector.
0049