PISTON PUMP (BRAKE, HYDRAULIC FAN) HIGH PRESSURE STALL TEST AND ADJUST CONTINUED
21. Release hydraulic system pressure. Pump service brake pedal at intervals of 1 second on and one second off
for at least 110 applications.
22. Remove tube cap (Figure 14, Item 4) from fan motor housing (Figure 14, Item 3).
23. Remove machine thread plug (Figure 14, Item 1) and O-ring (Figure 14, Item 2) from hydraulic oil inlet line
(Figure 14, Item 5).
Figure 14. Plug and Cap.
0044
24. Install hydraulic oil inlet line (Figure 15, Item 1) on fitting (Figure 15, Item 2).
Figure 15. Oil Line and Adapter.