TM 5-3805-293-23-2
0036
FAN SPEED CALIBRATION PROCEDURE CONTINUED
00036
6. Turn ignition switch and battery disconnect switch to the OFF position (TM 5-3805-293-10).
7. Remove test equipment.
8. If machine is equipped with arctic heater, install battery box (WP 0335).
END OF TASK
Calibration for Minimum Fan Speed
00036
N OT E
Engine Cooling Fan Minimum Speed calibration screen displays instructions for fan
calibration.
Top display area displays status parameters that are monitored during calibration.
Middle display area displays information about status of calibration.
Display area on bottom will dsplay conditions for setup and instructions for calibration.
i
1. Return to Fan Speed Calibration Procedure in this work package, and perform steps 2 to 4.
2. Select Engine Cooling Fan Minimum Speed.
3. Set parking brake, and operate engine at high idle by fully depressing and holding accelerator pedal (TM 5-
3805-293-10).
0036-19