TM 5-3805-293-23-2
0029
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2167-06 Circle Left Solenoid
6. Using MSD (WP 0006), select
2167-06 Code Active - Repeat
Current Above Normal -
Implement 120M and verify 2167- troubleshooting code from the
Continued
06 is active.
beginning.
2167-06 Code Not Active -
Troubleshooting complete.
System Response:
2167-13 Blade Sideshift
ECM will log a diagnostic code.
bration
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 2167-13
is Active.
1. Connect MSD (WP 0006). Select 2167-13 Code Active - Proceed to
Implement 120M and verify 2167- Test Step 2.
13 is active.
2167-13 Code Not Active -
Troubleshooting complete.
Test Step 2. Verify Other Diagnostic
Codes are Not Active.
1. Using MSD (WP 0006) verify
2167-03, 2167-05, or 2167-06 Code
2167-03, 2167-05, or 2167-06 are
Active - Troubleshoot other
not active.
diagnostic codes first in this work
package.
2167-13 Code Only Active - Proceed
to step 2.
2. Calibrate circle left solenoid, refer
Circle Left Solenoid Cannot Be
to Any Implement Moves with
Calibrated - Replace circle left
Joystick in Hold Position (WP
Proceed to step 3.
Circle Left Solenoid Calibrated -
Proceed to step 3.
2167-13 Code Active - Repeat
3. Using MSD (WP 0006), select
Implement 120M and verify 2167- troubleshooting code from the
beginning.
13 is active.
2167-13 Code Not Active -
Troubleshooting complete.
0029-57