TM 5-3805-293-23-2
0023
Table 1. Cab Electrical Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
13. One or Both Brake
Resistance Less Than 5.0 Ohms -
Lights Do Not Operate,
resistance between cab upper
Replace RH turn relay (WP 0009, Fig-
Turn Signals Operate
wiring harness connector P-C11
ure 328) and LH turn relay (WP 0009,
Normally - Continued
(WP 0009, Figure 286) terminal 9
Figure 326).
Connect the control indicator harness
should be less than 5.0 ohms.
connector PE-C11 (WP 0009, Figure
287) to cab lower wiring harness con-
nector P-C11 (WP 0009, Figure 286)
(WP 0283).
Connect the control indicator harness
connector PE-C10 (WP 0009, Figure
288) to control indicator switch (WP
0009, Figure 289).
Proceed to step 4.
Proceed to Test Step 9.
4. Turn control indicator switch to
Right and Left Brake Lights Do Not
position SER. DRIVE, have an
Operate - Repeat troubleshooting
assistant apply the service brakes
from the beginning.
(TM 5-3905-293-10) and observe
Right and Left Brake Lights Oper-
the brake lights from the rear of
ate - Troubleshooting complete.
the machine and verify both brake
lights operate.
Test Step 9. Check for Open Circuit
in Cab Upper Wiring Harness.
1. Disconnect the cab upper wiring
harness connector R-C3 (WP
0009, Figure 91) from cab lower
wiring harness connector P-C42
(WP 0009, Figure 90) (WP 0265).
0023-73