TM 5-3805-293-23-2
0022
Table 1. Cab Heating, Air Conditioning, and 12 Volt Power Inverter Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Heater Does Not Blow
3.
Warm When Tempera-
ceed to step 4.
ture Control Panel Is Set
nector R-C22 (WP 0009, Figure
Resistance More Than 5.0 Ohms -
On Maximum Heat - Con-
386) terminal 11 and harness con-
Replace cab upper wiring harness
tinued
nector P-C3 (WP 0009, Figure 34)
(WP 0265).
terminal 41.
Connect harness connector CM-C1
Resistance should be less than
(WP 0009, Figure 272) to harness
5.0 ohms.
connector P-C16 (WP 0009, Figure
273).
Connect cab lower wiring harness
harness connector CM-C7 (WP 0009,
Figure 271) to water valve actuator
(WP 0009, Figure 270) (WP 0294).
Proceed to step 15.
4. Disconnect harness connector
CM-C1 (WP 0009, Figure 272)
from harness connector P-C16
(WP 0009, Figure 273).
ceed to step 6.
nector R-C1 (WP 0009, Figure
Resistance More Than 5.0 Ohms -
32) terminal 41 and harness con-
Replace cab lower wiring harness
nector P-C16 (WP 0009, Figure
(WP 0266).
273) terminal 3.
Connect upper cab wiring harness
Resistance should be less than
connector R-C22 (WP 0009, Figure
5.0 ohms.
386) to HVAC control panel (WP
0009, Figure 385) (WP 0265).
Proceed to step 15.
ceed to step 7.
nector CM-C1 (WP 0009, Figure
Resistance More Than 5.0 Ohms -
272) terminal 3 and harness con-
Replace cab lower wiring harness
nector CM-C7 (WP 0009, Figure
(WP 0266).
271) terminal D
Connect upper cab wiring harness
Resistance should be less than
connector R-C22 (WP 0009, Figure
5.0 ohms.
386) to HVAC control panel (WP
0009, Figure 385) (WP 0265).
7. Connect upper cab wiring har-
ness connector R-C22 (WP 0009,
Figure 386) to HVAC control
panel (WP 0009, Figure 385) (WP
0265).
0022-8