Table 2. Engine Troubleshooting with Codes for the 120M Motor Grader - Continued.
Table 2. Engine Troubleshooting with Codes for the 120M Motor Grader - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 1
Page Navigation
  446    447    448    449    450  451  452    453    454    455    456  
img
. . . .
TM 5-3805-293-23-1
0011
Table 2. Engine Troubleshooting with Codes for the 120M Motor Grader - Continued.
CDI FMI CODE
ERROR/EVENT
CORRECTIVE ACTION
1627-05 Fuel Pump Relay
Test Step 1. Verify Diagnostic Code
Current Below Normal -
is Active.
Continued
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a
connection is found, correct the problem and verify that this diagnostic
code is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
1. Connect MSD (WP 0006). Select
Engine ECM C6.6 120M.
2. Verify diagnostic code 1627-05 is
Diagnostic Code 1627-05 Active -
active.
Proceed to Test Step 2.
Test Step 2. Test Relay Control Cir-
cuit.
1. Turn the ignition switch to the
OFF position.
2. Disconnect harness connector
FE-C4 (WP 0009, Figure 35) from
fuel prime pump relay.
3. Turn ignition switch to the ON
position.
N OT E
Do not disable fuel pump override; fuel pump override may turn off after
2 minutes.
4. Perform Fuel Pump Command
Override (WP 0035) to force fuel
pump relay On.
5. Using a digital multimeter, mea-
Voltage OK (18-24 Volts) - Replace
sure voltage supply circuit 150-
fuel pump relay (Fuel Transfer Pump,
RD for voltage between fuel prime
Test Step 4, WP 0035).
pump relay harness connector
Voltage NOT OK - Proceed to Test
FE-C4 (WP 0009, Figure 35) and
Step 3.
Terminal 5 and 2 ground.
Voltage should be within 18 - 24 Volts.
0011-149
Change 1