BRAKE ACCUMULATOR TEST
CENTERSHIFT CYLINDER SOCKET INSPECTION

Operator Manual For Motorized Road Grader Model 120M
Page Navigation
  241    242    243    244    245  246  247    248    249    250    251  
img
TM 5-3805-293-10
0016
TESTING CONTINUED
00016
2. Start engine and run for at least one minute to increase accumulator pressure. Alert indicator should go off
when pressure increases.
3. Shut down engine after one minute or when indicator goes off, whichever is longer.
4. With ignition in ON position, apply and release service brake pedal a minimum of five times, to decrease
accumulator pressure, until alert indicator illuminates.
5. Notify Field Level Maintenance if alert indicator illuminates before the minimum five applications of the service
brake pedal.