TM 5-3805-261-23-2
HYDRAULIC CONTROL VALVES REPAIR - CONTINUED
0332 00
DISASSEMBLY - CONTINUED
CAUTION
Do not place machined surfaces of manifolds or valves on unprotected surface. Scratches or nicks will per-
mit valve leakage.
5.
Separate housings (1 and 6) and valve (8) assemblies.
6.
At each separation surface, remove and discard two preformed packings (7), seal (9), and preformed packings
(10 and 11).
6
7
8
11
7
9
10
9
10
11
7
1
12
11
10
9
13
397-1547
0332 00-3