TRANSMISSION OIL COOLER MAINTENANCE - CONTINUED
TRANSMISSION OIL FILLER AND OIL LEVEL GAUGE REPLACEMENT

Maintenance Manual For Grader, Road, Motorized, Diesel Engine Driven, Heavy, Commercial Construction Equipment
Page Navigation
  169    170    171    172    173  174  175    176    177    178    179  
img
.
TM 5-3805-261-23-2
TRANSMISSION OIL COOLER MAINTENANCE - CONTINUED
0298 00
INSTALLATION - CONTINUED
3.
Install adapter (14), elbow (13), and adapter (12).
4.
Slide clamp (11) onto water hose (10).
5.
Install water hose (10) and clamp (11) onto adapter (12).
NOTE
Lightly lubricate all preformed packings with clean oil before installation.
6.
Install new preformed packing (9), oil line (8), and two bolts (7) on transmission oil cooler core (3).
7.
Install new preformed packing (4), oil line (5), and two bolts (6) on transmission oil cooler core (3).
8.
Connect air line (1) on elbow (2).
14
13
1
12
2
11
9
8
3
10
7
4
5
6
397-4155
9.
Install transmission sampling unit (WP 0154 00).
10.
Install left side engine panel (WP 0182 00).
11.
Fill radiator to proper level (WP 0065 00).
12.
Turn battery disconnect switch to ON position and start engine (TM 5-3805-261-10).
13.
Check for leaks.
14.
Stop engine.
END OF WORK PACKAGE
0298 00-9/(-10 Blank)