TM 5-3805-261-23-1
PRIMARY AND SECONDARY FILTER ELEMENTS REPLACEMENT - CONTINUED
0037 00
INSTALLATION - CONTINUED
4.
If removed, install new preformed packing (4) in cover (3).
NOTE
Hand tighten two eyebolts.
2
5.
Install cover (3) on air cleaner (2) and secure with two
eyebolts (1).
1
1
4
3
397-118
6.
Reset air cleaner indicator by pushing in button on bottom of air cleaner indicator (TM 5-3805-261-10).
NOTE
If air cleaner indicator shows red after performing this procedure, replacement of primary and/or secondary
filters may be necessary.
7.
Close left side engine door (TM 5-3805-261-10).
END OF WORK PACKAGE
0037 00-4