TM 5-3805-261-23-1
PRIMARY AND SECONDARY FILTER ELEMENTS REPLACEMENT - CONTINUED
0037 00
REMOVAL
CAUTION
Never service air cleaner with engine running. Engine damage could result if service is performed with
engine running.
1.
Loosen two eyebolts (1) and remove cover (3) from air cleaner (2).
2.
Inspect preformed packing (4) located inside of cover (3). Remove and discard preformed packing only if damaged.
2
1
1
4
3
397-118
3.
Remove primary filter element (8) from air cleaner (2).
4.
Remove six nuts (5).
CAUTION
If secondary filter element is difficult to remove, gasket on bottom of secondary filter element may be stick-
ing to air cleaner housing. Ensure this area on filter housing is thoroughly cleaned prior to installation of sec-
ondary filter element to prevent an air leak past secondary filter.
NOTE
Air cleaner is not secured after removing
5
secondary filter element and attaching
nuts.
5.
Remove secondary filter element (7) and gasket (6)
2
from air cleaner (2). Discard gasket.
6
7
8
397-120
0037 00-2