TM 5-3805-261-20
SENDING UNITS AND WARNING SWITCHES MAINTENANCE.
7-97.
Ether Start Switch. (Sheet 2 of 2)
REMOVAL
1.
Remove screw (1) and washer (2,
Figure 7-146) from switch (4) on front, left
side of engine.
NOTE
All
wire,
cable
and
harness
assemblies must be tagged before
disconnecting to aid in installation.
2.
Disconnect wire assembly (3).
3.
Remove switch (4) from top of water pump
(5).
CLEANING
Clean all parts. Refer to Chapter 2.
INSPECTION
Inspect all parts. Refer to Chapter 2.
INSTALLATION
1.
Install switch (4) on top of water pump (5,
Figure 7-146).
2.
Position wire assembly (3).
3.
Install washer (2) and screw (1) on switch
(4).
NOTE
Return
130C
Grader
to
original
equipment condition.
Figure 7-146
End of Task
7-239