TM 5-3805-261-20SENDING UNITS AND WARNING SWITCHES MAINTENANCE.7-97.Ether Start Switch. (Sheet 2 of 2)REMOVAL1.Remove screw (1) and washer (2,Figure 7-146) from switch (4) on front, leftside of engine.NOTEAll wire, cable and harnessassemblies must be tagged beforedisconnecting to aid in installation.2.Disconnect wire assembly (3).3.Remove switch (4) from top of water pump(5).CLEANINGClean all parts. Refer to Chapter 2.INSPECTIONInspect all parts. Refer to Chapter 2.INSTALLATION1.Install switch (4) on top of water pump (5,Figure 7-146).2.Position wire assembly (3).3.Install washer (2) and screw (1) on switch(4).NOTEReturn 130C Grader to originalequipment condition.Figure 7-146End of Task7-239