TM 5-3805-261-20
Section VII. OPERATORS PANEL CONSOLE TROUBLESHOOTING.
7-25.
GENERAL INFORMATION. This section lists the common operators panel console malfunctions which may
occur during the operation of the 130G Grader. You should perform the tests, inspections and corrective actions in the
order listed. Follow the troubleshooting procedures listed below step-by-step until you can go no further.
7-26.
OPERATORS PANEL CONSOLE TROUBLESHOOTING PROCEDURES. This section cannot list all possible
malfunctions, nor can it list all possible tests, inspections or corrective actions. If a malfunction is not listed, contact your
supervisor.
OPERATORS PANEL CONSOLE TROUBLESHOOTING AND MAINTENANCE PROCEDURES.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
a.
OPERATORS PANEL VIBRATES.
Check the operators panel mounting bolt (Figure 7-42).
Figure 7-42
If the mounting bolt is loose--tighten. If the mounting bolt is stripped, damaged or defective--replace. Refer to
paragraph 7-33.
7-73