TM 5-3805-261-20
ELECTRICAL SYSTEM. (cont)
7-9.
Starting System STE/ICE Tests. (cont)
g.
TEST 89. 0-45 VOLTS (cont)
1.
Positive Voltage Drop (cont)
(b)
STARTER SOLENOID
(1)
Refer to VTM-General Setup and Checkout Instructions in TM 9-4910-571-12 & P. Connect
power cable to battery (Figure 6-4).
Figure 6-4.
(2)
Attach black lead clip to terminal C (Figure 7-12). Attach red lead clip to battery positive
terminal (Figure 7-16). Make sure that all electrical contacts are clean.
Figure 7-12.
Figure 7-16.
(3)
Perform test using procedure TEST 89 as instructed in TM 9-4910-571-12 & P.
(4)
Maximum voltage drop allowable is 1.0 volts.
(5)
Return vehicle to its original condition.
7-32