TM 5-3805-261-20ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES. (cont)LegendQ - QuarterlyB - BiannuallyS - SemiannuallyH - HoursA - AnnuallyMi - MilesITEM TO BE INSPECTEDPROCEDURE: CHECK FOR AND HAVE REPAIRED,INTERVALFILLED OR ADJUSTED AS NEEDED. PERFORMITEM NO.QSABHMIALL OPERATOR PMCS FIRST.8•500COOLINGSYSTEMWARNINGThe cooling system is pressurized.Personal injury may result whenremoving the radiator cap after operatingtemperature is reached. If it becomesnecessary to check the coolant levelduring operation, use proper protectionwhen removing the radiator cap.Check and replace thermostat or anti-freeze, if required.9• 500ENGINEOILTake oil sample. Refer to TB 43-0210, Army Oil AnalysisProgram (AOAP).10•500CYLINDERS,HYDRAULICTest cylinders for worn piston seals.4-9(4-10 blank)