TM 5-3805-261-20APPENDIX E. (cont.)TORQUE LIMITS. (cont.)d.TABLE E-4. TORQUE LIMITS FOR AIR FITTINGS, HOSE CLAMPS AND PLUGS.(1) SAE Flareless Fitting. Bottom tube into fitting body and tighten nut until sleeve grips tube firmly enough toprevent movement. Tighten nut 1 to 1 1/4 additional turn. For reassembly, tighten until a sharp rise intorque is felt, then tighten an additional 1/6 to 1/3 turn.(2) High-duty (Shear Sleeve) Tube Fittings. Bottom tube into the fitting body and tighten nut until a slightyield is felt, indicating that the sleeve has been sheared from the nut. Tighten nut an additional 1/2 turn.(3) Flex Fittings. Slide nut and sleeve over tubing. Bottom tube in counterbore of fitting body. Tighten nutuntil it bottoms on hex part of fitting body.TABLE E-4.TORQUE LIMITS FOR FLARELESS FITTINGSTube O.D.Torque for Non-MetallicOptional Turn Tightening--(Inch)and Copper TubingTurns After Finger TighteningLB-INTubingTubingNon-MetallicCopper.25075-1253 Turns2 Turns.375150-2004 Turns2 Turns.500250-3504 Turns2 Turns.625300-4003 1/2 Turns3 Turns.750400-5003 1/2 Turns3 TurnsE-4