TM 5-3805-261-202-4.GENERAL MAINTENANCE INFORMATION.m.ElectricalSystemComponentsandWiring.(7)Preserving Connectors.WARNINGWater-displacing corrosion preventive compound vapors can be harmful to eyes and lungs. Toavoid harm, keep the corrosion preventive away from heat, wear protective goggles, and use in awell-ventilated area.CAUTIONUse water-displacing corrosion preventive compound MIL-C-81309, Type III, Class 2 only, oninternal connector surfaces.(a)Where possible, hold connectors with opening pointing slightly downward. Spray an even, thin filmof compound over the male pin area of the connector and into the female socket openings.CAUTIONUse water-displacing corrosion preventive compound MIL-C-85054, Type I only, on externalconnector surfaces.(b)After preserving connectors internally, assemble connectors. Wipe the outer surface of theconnector shell with a lint-free cloth dampened with cleaning compound MIL-C-81302. Spray a thin coating of water-displacing corrosion preventive compound MIL-C-85054, Type I, on all external surfaces of the connector set. Make surethe area where the connector set comes together is completely covered.(c)Wipe away excess spray with a lint-free cloth.(8)Soldering Techniques.WARNINGCleaning compound can cause skin rash and can give off harmful vapors. To avoid injury, use in awell-ventilated area. Wash immediately with soap and water if compound gets on skin or clothing.NOTEElectrical Maintenance/Repair Kit, 12285360, contains instructions and tools needed for repair andreplacement of connectors, contacts and wires.2-15