LO 5-3805-237-12
NOTES - CONTINUED:
AOAP laboratory. When AOAP laboratory support is not
available, change oil each 100 hours.
16. CIRCLE FLANGE. Clean circle flange with a
solution of OE/HDO and Diesel Fuel, mixed one quart
(0.946 L) OE/HDO to one gallon (3.78 L) of Diesel Fuel.
After cleaning, wipe dry and apply a light coat of GO with
a clean rag or shop towel.
17. LUBRICANTS. The following is a list of lubricants
with military symbols and applicable specification
numbers.
OE/HDO
MIL-L-2104
GO
MIL-L-2105
GAA
MIL-G-10924
OEA
MIL-L-46 167
BFS
MIL-B-46176
(SD), Type II
P-D-680
Copy of this Lubrication Order will remain with the
equipment at all times, instructions contained herein are
mandatory.
By order of the Secretary of the Army:
JOHN A. WICKHAM, JR.
General, United States Army
Chief of Staff
OFFICIAL:
ROBERT M. JOYCE
Major General, United States Army
The Adjutant General
DISTRIBUTION:
To be distributed in accordance with DA Form 12-25B,
Operator and Organizational maintenance requirements
for Graders.
U.S. GOVERNMENT PRINTING OFFICE: 2000 O - 461-699 (10406)
TA 220145
CARD 10 OF 10