LO 5-3805-237-12
NOTES - CONTINUED:
9. LATERAL SHIFT HOUSING/POWER CONTROL
BOX VERTICAL DRIVE HOUSING. Check level each
to meet the temperature ranges prescribed in the Key,
50 hours. Change gear lubricant only when required by
OEA lubricant is to be used in place of OE/HDO-10
lubricant for all temperature ranges where OE/HDO-10 is
other foreign material. After refill, operate for 5 minutes,
check for leaks and bring oil level to fill plug opening.
3. OIL CAN POINTS. Each 50 hours lubricate control
10. HYDRAULIC OIL FILTER. Each 500 hours, remove
linkage, pins and clevises, and all exposed adjusting
element, clean filter housing and install new element.
threads with EO/HDO.
After replacement, operate hydraulic system for 5
minutes, check for leaks, check level and bring to
"FULL" mark.
4. WHEEL BEARINGS. Each 1000 hours remove,
clean, inspect, lubricate and assemble.
11. LOWER TRANSMISSION/UPPER TRANSMISSION
AND SHIFTER HOUSING. Check level each 50 hours.
5. SCARIFIER LIFT HOUSING/SCARIFIER GEAR
Change gear lubricant only when required by
REDUCTION HOUSING. Check level each 50 hours.
Change gear lubricant only when required by
other foreign material. After refill, operate for 5 minutes,
check for leaks and bring oil level to fill plug opening.
other foreign material. After refill, operate for 5 minutes,
check for leaks and bring oil level to fill plug opening.
12. ENGINE OIL LEVEL HOT OR COLD CHECK. Cold
engine, oil level should be at high mark on dipstick. Hot
6. LIFT
HOUSING/LIFT
GEAR
REDUCTION
engine, oil level must be between high and low marks on
HOUSING. Check level each 50 hours. Change gear
dipstick (allow to set 5 minutes before checking).
lubricant only when required by maintenance repair
After refill, operate for 5 minutes, check for leaks and
13. ENGINE OIL FILTER. Filter is to be replaced each
bring oil level to fill plug opening.
time an engine oil change is directed by AOAP
laboratory.
After installing new filter element, fill
crankcase, operate engine 5 minutes, check housing for
7. FRONT WHEEL LEAN HOUSING.
leaks, check crankcase oil level and bring to full mark.
Check level each 50 hours. Change gear lubricant only
When AOAP laboratory support is not available, install
when
required
by maintenance repair action,
new filter element each 100 hours.
refill, operate for five minutes, check for leaks and bring
oil level to fill plug opening.
14. TANDEM DRIVES.
Each 1000 hours drain
tandems. Place tandems in uphill position and remove
tandem level and drain plug.
8. CIRCLE REVERSE HOUSING/CIRCLE REVERSE
TRANSFER HOUSING. Check level each 50 hours.
Change gear lubricant only when required by
15. ENGINE. Oil is to be changed each time an engine
oil change is directed by
other foreign material.
After refill, operate for five
minutes, check for leaks and bring oil level to fill plug
TA 220144
opening.
CARD 9 OF 10