TM 5-3805-293-23-2
0023
Table 1. Cab Electrical Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
19. One or Both Backup
4.
Voltage Between 18 and 26 Volts -
Lights Do Not Operate
voltage between connector P-C11
Proceed to Test Step 8.
and/or Backup Alarm
(WP 0009, Figure 286) terminals
Voltage Less Than 18 Volts - Pro-
Does Not Operate - Con-
1 and machine ground. Voltage
ceed to Test Step 7
tinued
should be 18 to 26 volts.
Test Step 7. Check for Bad Fuse.
1. Turn battery disconnect switch
and ignition switch to the ON posi-
tion (TM 5-3805-293-10).
2. Remove fuse F38 from cab fuse
panel (TM 5-3805-293-10).
3. Visually inspect fuse F38 for open
Resistance Less Than 5.0 Ohms -
Replace cab lower wiring harness
(WP 0266).
minals of fuse F38. Resistance
Connect the backup alarm relay (WP
should be less than 5.0 ohms.
0009, Figure 141) to rear chassis wir-
ing harness connector FA-C33 (WP
0009, Figure 142) (WP 0188).
Connect the rear lamps harness con-
nector AG-C20 (WP 0009, Figure 311)
to rear chassis wiring harness con-
nector FA-C29 (WP 0009, Figure 310)
(WP 0178).
Install fuse F38 to cab fuse panel
(TM 5-3805-293-10).
Proceed to step 4.
or Greater - Replace fuse F38.
Connect the control indicator harness
connector PE-C11 (WP 0009, Figure
287) to cab lower wiring harness con-
nector P-C11 (WP 0009, Figure 286)
(WP 0283).
Connect the backup alarm relay (WP
0009, Figure 141) to rear chassis wir-
ing harness connector FA-C33 (WP
0009, Figure 142) (WP 0188).
Connect the rear lamps harness con-
nector AG-C20 (WP 0009, Figure 311)
to rear chassis wiring harness con-
nector FA-C29 (WP 0009, Figure 310)
(WP 0178).
Proceed to step 4.
0023-122