Table 1. Cab Electrical Troubleshooting Procedures - Continued.
Table 1. Cab Electrical Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  247    248    249    250    251  252  253    254    255    256    257  
img
TM 5-3805-293-23-2
0023
Table 1. Cab Electrical Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. One or Both Headlights
Test Step 5. Check for Shorted
Do Not Operate in Low
Front Worklight Wiring Harness.
Beam - Continued
1. Turn battery disconnect switch
and ignition switch to the OFF
position (TM 5-3805-293-10).
2. Disconnect the connector AA-C2
(WP 0009, Figure 291) from right
headlight.
3. Using digital multimeter, measure  Continuity - Proceed to Test Step 6.
for continuity between front work  No Continuity - Proceed to Test
light wiring harness connector CL- Step 7.
C18 (WP 0009, Figure 294) termi-
nal 5 and 8. There should be no
continuity.
Test Step 6. Check for Shorted
Front Lighting Wiring Harness.
1. Disconnect the front work light
wiring harness connector CL-C26
(WP 0009, Figure 293) from front
lighting wiring harness connector
A-C3 (WP 0009, Figure 292) (WP
0196).
2. Disconnect the front work light
wiring harness connector CL-C24
(WP 0009, Figure 393) from front
lighting wiring harness connector
A-C4 (WP 0009, Figure 394) (WP
0196).