Table 1. Cab Heating, Air Conditioning, and 12 Volt Power Inverter Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Blower Motor Does Not
5. Connect cab upper wiring har-
Turn On In One or More
ness connector R-C22 (WP 0009,
Speeds - Continued
Figure 386) to climate control
panel (WP 0009, Figure 385) (WP
0293).
6. Disconnect harness connector P-
C16 (WP 0009, Figure 273) from
harness connector CM-C1 (WP
0009, Figure 272) (WP 0266).
ceed to step 8.
nector P-C3 (WP 0009, Figure 34)
Resistance More Than 5.0 Ohms -
terminal 47 and harness connec-
Replace cab lower wiring harness
tor P-C16 (WP 0009, Figure 273)
(WP 0266).
terminal 6.
Proceed to step 15.
Resistance should be less than
5.0 ohms.
8. Connect cab upper wiring har-
ness connector R-C1 (WP 0009,
Figure 33) to cab lower wiring har-
ness connector P-C3 (WP 0009,
Figure 34) (WP 0266).
9. Disconnect cab lower wiring har-
ness connector C (WP 0009, Fig-
ure 402) from blower resistor
terminal C (WP 0009, Figure
402).
ceed to step 11.
nector CM-C1 (WP 0009, Figure
Resistance More Than 5.0 Ohms -
272) terminal 6 and harness con-
Replace cab lower wiring harness
nector C (WP 0009, Figure 402).
(WP 0266).
Resistance should be less than
Proceed to step 15.
5.0 ohms.
11. Connect harness connector P-
C16 (WP 0009, Figure 273) to
harness connector CM-C1 (WP
0009, Figure 272) (WP 0266).
12. Turn battery disconnect switch
and ignition switch to the ON posi-
tion (TM 5-3805-293-10).
13. Turn fan speed switch to the
medium high speed setting.
0022-22