TM 5-3805-293-23-1
0011
Table 2. Engine Troubleshooting with Codes for the 120M Motor Grader - Continued.
CDI FMI CODE
ERROR/EVENT
CORRECTIVE ACTION
N OT E
1589-03 Turbocharger Inlet
Air Pressure Sensor Volt-
Wait at least 30 seconds in order for diagnostic codes to become active.
age Above Normal Code -
Continued
1589-03 Remains Active - Proceed
Engine ECM C6.6 120M, and
to Test Step 2.
check if diagnostic code 1589-04
1589-04 Becomes Active - ECM and
is active.
return circuit test OK, turbocharger
inlet air pressure sensor is faulty.
Replace turbocharger inlet air pres-
sure sensor (WP 0112).
9. Turn the ignition switch to the
OFF position.
10. Remove jumper wire from har-
Figure 26) terminal B and terminal
C.
11. Disconnect harness connector
harness connector FA-C18 (WP
12. Install a jumper wire between har-
ness connector FA-C18 (WP
0009, Figure 28) terminal 9 and
ground.
13. Turn the ignition switch to the ON
position.
N OT E
Wait at least 30 seconds in order fordiagnostic codes to become active.
Other diagnostic codes may become active during this step; ignore
these codes.
1589-03 Remains Active - Proceed
Engine ECM C6.6 120M, and
to step 15.
check if diagnostic code 1589-04
1589-04 Becomes Active - ECM and
is active.
signal circuit test OK, replace fuel
wiring harness.
15. Turn the ignition switch and bat-
tery disconnect switch to the OFF
position.
16. Remove jumper wire from har-
ness connector FA-C18 (WP
0009, Figure 28) terminal 9 and
ground.
0011-143
Change 1