TM 5-3805-293-10
0013
Table 1. Preventive Maintenance Checks and Services (PMCS)
with Lubrication Information - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL HOURS
SERVICE
PROCEDURE
CAPABLE IF:
67
After
0.2
Hydraulic Tank
(Cont.)
Sight Gauge
Figure 21. Hydraulic Oil Tank.
0013
68
After
NATO
a. Ensure NATO slave receptacle
Receptacle
cover is installed.
b. Close left rear access door.
REAR
69
After
Rear of
WARN I N G
Machine
Wear suitable eye protection and keep face and eyes
away from exhausting air tank drain valves. Failure to do
so may cause injury to personnel.
a. Check for damage to rear
Damage that would impair
blackout light, taillights, turn signal
operation is evident.
lights, and rear work light.
b. Check radiator grille and
Damage that would impair
backup alarm for debris and
operation is evident.
damage.