TM 5-3805-293-10
0009
MONITORING SYSTEM WARNINGS
0009
The Monitoring System provides three warning categories. The first warning category requires only operator
awareness. The second warning category requires a change to machine operation or the performance of mainte-
nance to the system. The third warning category requires immediate shutdown of the machine.
0009
Table 1.
WARNING
ALERT TO OPERATOR
ACTION REQUIRED
Category 1 Alert
Alert indicator activated.
1. Check Messenger system for alert
Machine system needs attention.
message.
2. Follow instructions on Messenger
system.
Category 2 Alert
Alert indicator activated.
1. Check Messenger system for alert
A change in machine operation is
message.
Action light activated.
required.
2. Follow instructions on Messenger
system.
Category 2S Alert
1. Check Messenger system for alert
Alert indicator activated.
message.
Immediate change in machine
Action light activated.
operation is required.
2. Follow instructions on Messenger
Action alarm sounds at a
system.
steady rate.
WARN I N G
Category 3 Alert
Alert indicator activated.
Immediate need to shut down
Action light activated.
Failure to follow this warning may result
machine.
Action alarm sounds at a
in injury or death to personnel or damage
pulse rate.
to equipment.
1. Shut down machine immediately.
2. Check Messenger system for alert
message.
3. Follow instructions on Messenger
system.
0009-2