TM 5-3805-261-34COOLING SYSTEM MAINTENANCE. (cont)3-34.WaterPump.(Sheet 2 of 9)DISASSEMBLY1.Remove two bolts (1) and washers (2, Figure3-179).2.Separate cover (3) and gasket (4) from housing(22). Discard gasket (4). Remove all gasketmaterial from mounting surfaces.3.Loosen bolt (5, Figure 3-180) ¼ turn.4.Using soft hammer, strike bolt (5) head toloosen impeller (7).5.Remove bolt (5) and washer (6, Figure 3-181).NOTEDo not pry impeller (7) out with ascrewdriver.6.Remove impeller (7).7.Remove and discard spring (8) and seal (9, Figure3-182).Go to Sheet 33-194Figure 3-182.Figure 3-181.Figure 3-180.Figure 3-179.