TM 5-3805-261-23-1
CENTERSHIFT LOCK ASSEMBLY REPLACEMENT - CONTINUED
0260 00
INSTALLATION
1.
Coat inside surface of housing assembly (15) with lubricating oil.
2.
Coat outside of pin (13) with lubricating oil.
3.
Position housing assembly (15) against blade lift bar (16), aligning holes of housing assembly with holes in blade lift
bar.
4.
Install pin (13) into housing assembly (15) and blade lift bar (16).
11
8
5.
Install plug (12) on housing (8).
6.
Install three washers (11).
12
397-823
7.
Install new preformed packing (10).
WARNING
Bolts that hold housing to blade lift bar must be tightened evenly, a thread or two at a time, to prevent injury
to personnel or damage to housing.
8.
Install spring (9), housing (8), two washers (7), and bolts (6).
10
8
9
7
6
397-822
0260 00-5