TM 5-3805-261-23-1
TRANSMISSION OIL SAMPLING VALVE AND LINE MAINTENANCE - CONTINUED
0154 00
REMOVAL - CONTINUED
5.
Remove two bolts (9) and transmission oil sampling valve (1).
1
9
397-471
DISASSEMBLY
1.
Remove drain cock (18), adapter (17), preformed packing (16), and adapter (15) from reducer (14). Discard preformed
packing.
2.
Remove nuts (13 and 11) and reducer (14) from
18
bracket (10).
3.
Remove reducer (12) from nut (13).
10
CLEANING AND INSPECTION
Clean and inspect all parts in accordance with WP
17
ASSEMBLY
16
1.
Install reducer (12) on nut (13).
2.
Install reducer (14) and nuts (11 and 13) on bracket
(10).
15
11
3.
Install adapter (15), new preformed packing (16),
adapter (17), and drain cock (18) on reducer (14).
12
14
13
397-472
INSTALLATION
1.
Install transmission oil sampling valve (1) and two bolts (9).
0154 00-3