TM 5-3805-261-20TRANSMISSION MAINTENANCE.8-10.Transmission Oil Filler and Oil Level Gage.(Sheet 2 of 30REMOVAL1.Remove bolt (1) and clamp (2, Figure 8-41).2.Remove bolt (3) and clamp (4).NOTEAll hose and tube assemblies mustbe tagged before disconnecting toaid in installation. Cap all hose andtube ends to prevent contamination.3.Remove two bolts (5), washers (6), tubeassembly (7) and seal (8, Figure 8-42).Discard seal (8).4.Remove gage (12, Figure 8-44).5.Remove bolt (9), lockwasher (10) and cap(11, Figure 8-43).6.Remove bolt (13) and washer (14)from clip(15).7.Slide clip (15) on hose (16).8.Remove two bolts (17), lock washers (18),tube assembly (19) and gasket (20, Figure8-44). Discard gasket (20). Remove allgasket material from mounting surfaces.CLEANINGClean all parts. Refer to Chapter 2INSPECTIONInspect all parts. Refer to Chapter 2.Figure 8-44Go to Sheet 3Figure 8-41Figure 8-42Figure 8-438-41